- Lifelike Materials: Intubation model uses thermoplastic elastomer material and PVC plastic. The touch and appearance are both very realistic
- Simulated: Adult intubation manikin teaching model is designed based on adult lung data. The branches of oral, nasal, pharyngeal, and bronchial models are highly similar to the relevant anatomical structures of the human body
- Electronic Alarm: Airway management trainer can be inserted based on feedback from lighting and music during use. If the intubation is completed correctly, the electronic controller will play music and the light will turn on; On the contrary, the alarm will sound and the lights will flash
- Two Intubation Methods: Intubation manikin can be inserted through the oral or nasal cavity for tracheal intubation. When the catheter is correctly inserted into the airway, the lungs expand significantly; When mistakenly inserted into the esophagus, the stomach will swell. This design provides practitioners with intuitive demonstrations, which is beneficial for memory and learning
- Wildly Application: Intubation practice kit could be used on training and teaching, needed by hospitals, medical college, emergency rescue. It is also suitable for medical college students, all kinds of on-site emergency personnel training, teaching demonstration through oral tracheal intubation technology and internship operation
Product description Airway Management Trainer Intubation 110V ●It can be oral nasal intubation training operations and teaching demonstration. ●During oral, nasal intubation training operation, insert the correct operation of the airway, electronic display and play music function, so the lungs inflate gas ●Oral, nasal intubation training operation, the wrong operation insert the esophagus, electronic display and alarm function. Stomach gas expansion ●Error makes laryngoscope cause tooth pressure, electronic alarm function ●Observed and compared to normal side and the other side becomes large pupils ●Indicating thyrocricocentesis site Soft touch silicone made, real skin touch NOT cheap plastic. Electronic showing, easy to operation. And quickly to know the reasult. The light and indicate the correct intubation; the alarm with lights occurs with the wrong procedure or when the laryngoscope compresses the teeth. Easy to plug and unplug, durable and saving time. Real showing lung and stomach. Realistic facial contours Come with carton box and portable bag, provide more protection, and convenience. 1. Cephalic operator station model.We will head back 80 degrees, so that the mouth, pharynx, trachea basic overlap line will mouth open. 2. Handheld model inserted aligned glottis, is inserted through the glottis about 0.4 inches, the controller flashes green and with music. Rapid removal of the catheter core, and then continue to rotate the catheter tube 1.5 inches in depth. 3. If the controller will flash red, and issued a "beep" sound, notices esophageal catheter is inserted by mistake, should quickly pull out re-inserted 4. Plug in the model flanking a dental pad, quit laryngoscope, with adhesive tape properly fixed catheter and dental pad. 5. Guide tube cuff with a syringe into the amount of air, the balloon tube end if no automatic ball, then closed with a clamp. 6. The outer end of the catheter is connected respirators, squeezing the bag, observe lung expansion